12 AWWA C651-05 4. Direct-feed chlorinators, which operate solely from gas pressure in the chlorine cylinder, shall not be used for the application of liquid chlorine. (The danger of using direct-feed chlorinators is that water pressure in the main can exceed gas pressure in the ...

http://sno-nsn.gov/component/rsfiles/view?path=Procurements%5CANSI-AWWA%20STANDARD%20C651-05.pdf&Itemid=929

Date added: June 9, 2014 - Views: 1

pdf
SECTION 02501 DISINFECTION OF WATER DISTRIBUTION SYSTEMS

A. American Water Works Association, AWWA C651, AWWA Standard for Disinfecting Water Mains. B. American Public Health Association, American Water Works Association and Water Pollution Control Federation, Standard Methods for the Examination of Water and Wastewater.

http://www.monson-ma.gov/Public_Documents/MonsonMA_WaterSewer/AppendixB.pdf

Date added: June 29, 2012 - Views: 80

pdf
New or Repaired Water Mains - Home | Water | US EPA

ANSI/AWWA Standard C651-92 suggests a temporary flushing/testing connection that includes ... American Water Works Association. 1993. ANSI/AWWA C600-93 - AWWA Standard for Installation of Ductile-Iron Water Mains and Their Appurtenances..

http://water.epa.gov/lawsregs/rulesregs/sdwa/tcr/upload/neworrepairedwatermains.pdf

Date added: December 23, 2011 - Views: 73

pdf
I. PURPOSE II. BACKGROUND - Ohio

American Water Works Association (AWWA) Standards for the disinfection of finished water storage facilities and water mains, which are referenced in rule ... AWWA Standard C651-05 Disinfection of Water Mains (2005). 4.

http://www.epa.ohio.gov/portals/28/documents/pws/OPR-05-002.pdf

Date added: October 5, 2012 - Views: 56

pdf
Water Main Breaks: A Quick Reference Guide - Ohio EPA Home

AWWA Standard C651-05. An advisory is required if any samples are E. coli or fecal coliform positive. 3. Collect special purpose samples for total coliform bacteria and chlorine residual. 4. Notify the appropriate Ohio EPA District Office of the

http://www.epa.ohio.gov/portals/28/documents/pws/main_break_qrf_final.pdf

Date added: December 4, 2011 - Views: 29

pdf
Standard Specifications Disinfecting Pipelines

Standard Specifications Disinfecting Pipelines Revised June 2013 33 01 10.15-2 1.06 REFERENCES A. Refer to current AWWA Standard C651 for Disinfecting Water Mains.

http://www.amwater.com/files/33%2001%2010.15%20-%20Disinfecting%20Pipeline.pdf

Date added: December 6, 2012 - Views: 37

pdf
SECTION 2620 - WATER MAIN DISINFECTION PART 1 - GENERAL 1.1 ...

Disposal of chlorinated water shall be in accordance with AWWA C651-05 and all federal, state, and local requirements. C. After final flushing and before the water main is placed in service, two (2) consecutive sets of

http://des.butlercountyohio.org/html/contractors/documents/2620.rev08.pdf

Date added: July 2, 2012 - Views: 29

pdf
Division of Drinking Water Checklist for Issuing Operating ...

☐ ANSI/AWWA C651-05 AWWA Standard for Disinfecting Water Mains Two consecutive sample sets (each 1200 feet, end-of-line, each branch, etc.), none positive, at least 24 hours apart ☐ ANSI/AWWA C652-02 AWWA Standard for Disinfection of Water-Storage Facilities

http://www.drinkingwater.utah.gov/documents/engineering/OperatingPermitCheckList.pdf

Date added: May 30, 2012 - Views: 119

pdf
City of Goodyear - Goodyear, AZ - Official Website

Disinfection of Mains Chlorination of all water mains shall be per AWWA C651-05. The method of chlorination used by the Contractor shall be approved by the City Inspector prior to use.

http://www.goodyearaz.gov/DocumentCenter/View/12965

Date added: November 27, 2013 - Views: 4

pdf
Chlorination / DeChlorination Procedures - PNWS-AWWA

FIELD CHLORINATION • AWWA/ANSI C651-05 – Disinfecting Water Mains • First standard approved Sept. 30, 1947 • Latest revision June 1, 2005

http://www.pnws-awwa.org/uploads/PDFs/conferences/2009/Dist_FriPM_Gordhammer_Chlor%20and%20Dechlor%20Proc.pdf

Date added: August 19, 2013 - Views: 14

pdf
Repair and Disinfection of Water Mains - Missouri Department ...

the latest ANSI/AWWA Standard for Disinfecting Water Mains C651-05, which covers both the disinfection of new water mains and repairs of existing water mains. However, copies of the standard must be purchased.

http://www.dnr.mo.gov/pubs/pub2442.pdf

Date added: September 8, 2012 - Views: 14

pdf
ANSI/AWWA C104 ANSI/AWWA C110 ANSI/AWWA C111

ANSI/AWWA C651 - Standards for Disinfecting Water Mains ASTM C31- Method of Making and Curing Concrete Compression and Flexure Test Specimens ... 660-06M.doc 3 of 14 Last Revised 1-05 MJ rubber gasket per ANSI/AWWA C111. Restraint (gripper) ...

http://www.monroecounty.gov/p/specs/5897.pdf

Date added: February 21, 2012 - Views: 163

pdf
15041 - Disinfection of Pipe & Water Storage Facilites

AWWA C651 Disinfecting Water Main AWWA C652 Tank Disinfection 1.03 RELATED WORK SPECIFIED ELSEWHERE ... 1.05 SUBMITTALS A. A written disinfection and dechlorination plan signed by a certified chlorinator shall be submitted ...

http://www.fpud.com/PDFDocuments/Construction%20Standards/Section%203%20Technical%20Specifications/15041%20-%20Disinfection%20of%20Pipe%20%26%20Water%20Storage%20Facilites.pdf

Date added: August 6, 2013 - Views: 19

pdf
DEPARTMENT OF ENVIRONMENTAL PROTECTION - DEP Document ...

C. Latest standards issued by the American Water Works Association (AWWA) and the American National Standards Institute (ANSI), including ANSI/AWWA Standard C651-05 - Disinfecting Water Mains. AWWA Standards are copyrighted materials. To place an order, please call AWWA

http://www.elibrary.dep.state.pa.us/dsweb/Get/Document-76813/383-2129-004.pdf

Date added: February 27, 2012 - Views: 16

pdf
Question of the Month

fected a water main according to AWWA Standard C651-05. The city was com-plaining because he used a method that was against city regulations. After some research, I found that the contractor used the tablet method of disinfection.

http://www.awwa.org/portals/0/files/resources/resource%20dev%20groups/standards%20program/documents/opflow20july2008.pdf

Date added: June 30, 2014 - Views: 1

pdf
OKLAHOMA STATE UNIVERSITY - BUILDING DESIGN STANDARDS

ANSI/AWWA Standard C651-05. D. When a subcontractor performs the disinfection procedure, it is the joint responsibility of both the General Contractor and designated subcontractor to comply with this procedure. 3.02 Specific Program Components

http://lrfp.okstate.edu/sites/default/files/documents/standards/02514%20disinfection%20procedures%20for%20water%20lines_030509.pdf

Date added: January 17, 2014 - Views: 1

pdf
STANDARD SPECIFICATIONS CHLORINATION OF WATER SYSTEM

Preliminary flushing of pipe required by AWWA C651 before chlorination is optional if interior is broom swept or in clean condition, as determined by Contractor. 02511-3 July 2005 ... 6 0.02 0.03 0.033 0.038 0.04 0.05 0.06 0.11 0.16 0.22 0.28 0.33 0.38

http://www.wsscwater.com/file/EngAndConst/Sect2005-spec/specs_2005/02511_Chlorination_Water_System.pdf

Date added: March 26, 2012 - Views: 10

pdf
SECTION 25 TESTING AND DISINFECTING WATER MAINS

25-1.05 Backflow Protection. ... AWWA C651 and these specifications. Disinfection requirements shall include preventive and corrective measures during construction, forms of chlorine and methods of application, final flushing, and bacteriological tests.

http://nidwater.com/wp-content/uploads/2012/04/O-Section-25-Testing-Disinfecting-Water-Mains.pdf

Date added: April 8, 2013 - Views: 21

pdf
ROGERS WATER UTILITIES WATER SYSTEM ROGERS, ARKANSAS

requirements of ANSI/AWWA C651-05 using the Continuous Feed Method, except as specified otherwise herein. c. The chlorine compound used for disinfection shall be calcium hydrochlorite in granular form. The calcium hydrochlorite must contain a minimum of 65 percent available ...

http://www.rwu.org/Files/Engineering/SSPEC/PDF%20Files/08/08-08%20MainDisinfection.pdf

Date added: June 5, 2013 - Views: 11

pdf
CHESTERFIELD COUNTY WATER AND SEWER SPECIFICATIONS

C651-92” to “Section 4 of AWWA C651-05”. 5-13, 5-14 & 5-15 Reformatted pages due to language added on page 5-12. 5-16 Under 4. Method of Chlorine Application and Testing – added

http://www.chesterfield.gov/WorkArea/linkit.aspx?LinkIdentifier=id&ItemID=10884

Date added: May 8, 2013 - Views: 6

pdf
STANDARD SPECIFICATIONS CHLORINATION AND DECHLORINATION

Preliminary flushing of pipe required by AWWA C651 before chlorination is optional if interior is broom swept or in clean condition, as determined by ... 0.05 : 0.06 . 0.11 : 0.16 . 0.22 : 0.28 . 0.33 : 0.38 . 2 . 0.01 . 0.02 : 0.03 . 0.04 : 0.05 . 0.06 : 0.07 . 0.08 : 0.09 . 0.10 : 0.20 . 0.30 ...

http://www.wsscwater.com/file/02511%20Chlorination%20and%20Dechlorination%20-%202011.pdf

Date added: October 3, 2012 - Views: 12

pdf
SECTION C-2 - VALVES - Wilmington, De

Mains, ANSI/AWWA C651-05. The City of Wilmington, Delaware Department of Public Works Standard Specifications Rev. 022010 Page 4 of 4 All work of flushing and sterilizing shall be the responsibility of the Contractor.

http://www.wilmingtonde.gov/docs/337/C-2_Rev012010_3_.pdf

Date added: November 8, 2012 - Views: 22

pdf
TESTING AND DISINFECTION PART 1 - GENERAL 1.01 SECTION ...

1.05 DELIVERY, STORAGE, AND HANDLING Follow the General Provisions (Requirements) and Covenants. ... Perform operations according to AWWA C651 in the sequence below. Successfully complete each operation before continuing to the next operation.

http://xa.yimg.com/kq/groups/19886682/44321100/name/AWWA%20c600.pdf

Date added: June 30, 2014 - Views: 1

pdf
Performance Testing of Pressure Pipeline - St Lucie County ...

E. ANSI/AWWA C651 - Standard for Disinfecting Water Mains. F. ANSI/AWWA C900 - Standard for PVC Pipe, 4"-12" for Water Distribution. 1.4 SUBMITTALS A. Test Reports: Indicate results comparative to specified requirements. SLCU 1/00 02760-2 PERFORMANCE TESTING B ...

http://www.stlucieco.gov/pdfs/02760.pdf

Date added: October 10, 2011 - Views: 271

pdf
AWU Disinfection Plans for Potable Waterlines

is to more closely align the City of Austin requirements with AWWA C651 guidelines and to simplify the ... www.awwa.org – AWWA C651-05 Disinfection Water Mains; Webcast – “Advanced Disinfection of Pipelines and Storage Facilities”

http://www.aceatx.com/documents/disinfection_plans.pdf

Date added: March 8, 2012 - Views: 14

pdf
02675 Disinfection of Water Lines - Bassett Engineering

A. AWWA C651 - Disinfecting Water Mains. B. County and PA DEP Regulations. C. DEP Water Supply Manual. 1.04 STERILIZATION ... 3.05 TOTAL COLIFORM TESTING A. After final flushing and before the water main is placed in service, a water sample or

http://www.bassetteng.com/PDF/Collomsville/02675_%20DisinfectionofWaterLines.pdf

Date added: August 19, 2013 - Views: 4

pdf
02080 Ductile Iron Pipe and Fittings

American Water Works Association (AWWA) AWWA C104 Cement-Mortar Lining for Ductile- Iron Pipe and Fittings ... AWWA C651 Disinfecting Water Mains 1.05 SUBMITTALS: IN ACCORDANCE WITH REQUIREMENTS OF GENERAL SPECIFICATIONS, ...

http://www.ci.chelsea.ma.us/Public_Documents/ChelseaMA_Bids/Prior%20Bids/Lash,%20Gardner%20and%20John%20St%20Utility%20and%20Roadway%20Improvements/Specifications/DIVISIONS%202%20-%203.pdf

Date added: September 16, 2013 - Views: 4

pdf
SECTION 15020 DISINFECTING PIPELINES - American Water

.05 REFERENCES. Refer to current AWWA Standard for Disinfecting Water Mains C651. PART 2 PRODUCTS ... Methods to be used for disinfection are those detailed in ANSI/AWWA C651 Disinfecting Water Mains. .03 WATER MAINS . Three (3) ...

http://www.amwater.com/files/15020-DisinfectingPipeline.pdf

Date added: July 16, 2012 - Views: 11

pdf
Construction Meter Agreement - Goodyear, AZ

2.5ft/s per AWWA C651-05. 15. Materials. All materials used by Contractor shall meet National Sanitary Foundation Standards for drinking water, the City Temporary Jumper Connection Detail (G-3356) standards and City of Goodyear Approved Materials list for Water.

http://www.goodyearaz.gov/DocumentView.aspx?DID=3190

Date added: March 7, 2013 - Views: 2

pdf
SECTION 02516 WATER LINES – DISINFECTION AND TESTING

3.1 DISINFECTION AND SAMPLING (Reference AWWA C651 for further details.) A. The basic disinfection procedure consists of the following steps: ... 10 0.034 0.171 0.341 1.023 0.41 2.05 4.09 12.27 0.050 0.25 0.50 1.51 12 0.0 0.2 0.5 1 ...

http://www.kub.org/prc/prcspecs.nsf/a2f228d1507aea5b8525750b00585495/f3390882d8f1df238525751500613583/$FILE/02516v1%20-%20Water%20Lines-%20Disinfection%20and%20Testing.pdf

Date added: May 22, 2013 - Views: 5

pdf
Procedures for New Watermains 5/7/2007 - Richmond Hill, Ontario

Procedures for New Watermains 5/7/2007 STANDARD (A) …continued 3. Swabbing (AWWA C651-05 Sec. 4.3.6) Request for Isolation Valve Operation is required for the swabbing procedure.

http://www.richmondhill.ca/documents/procedures_for_new_watermains.pdf

Date added: March 26, 2012 - Views: 3

pdf
Section 5030 - Testing & Disinfection - Statewide Urban ...

3.05 PRESSURE AND LEAK TESTING A. Remove debris from within the pipe. Clean and swab out pipe, if required. ... Test water mains according to AWWA C651, including collection of two consecutive sets of acceptable bacteria samples 24 hours apart.

http://www.iowasudas.org/manuals/specs/div5/5030.pdf

Date added: January 10, 2014 - Views: 6

pdf
APPENDIX 7 Watermain Testing Requirements - Town of Newmarket

ANSI/AWWA C651-05. Supervision, Testing and Records The Consulting Engineer and Town shall witness all cleaning, disinfection, hydrostatic testing and sampling activities. The Workforce carrying out the

http://newmarket.ca/en/townhall/resourcelibrary/17_Appendix7_WatermainTestingRequirements.pdf

Date added: January 12, 2014 - Views: 1

pdf
WATER AGENCIES’ STANDARDS STANDARD SPECIFICATIONS SECTION ...

1.05 SUBMITTALS A written disinfection and dechlorination plan, including all methods and equipment to be used, ... with a liquid chlorine solution in accordance with AWWA C651 and as specified herein. Upon connection to the main, ...

http://www.sdwas.com/Documents/Vol2/Section2/Division15/StdSpec15041_11-23-11.pdf

Date added: September 8, 2012 - Views: 12

pdf
STANDARD SPECIFICATIONS SECTION: 33 11 00 WATER MAINS ...

.15 ANSI / AWWA C600-05 Installation of Ductile Iron Water Mains and Their Appurtenances. .16 ANSI / AWWA C606-04 Grooved and Shoulder Joints. .17 ANSI / AWWA C651-05 Disinfecting Water Mains. .18 ANSI / AWWA C800-05 Underground Service Line Valves and Fittings. .19 ANSI ...

http://www.halifax.ca/hrwc/documents/StandardSpecifications2013.pdf

Date added: June 14, 2013 - Views: 4

pdf
RMC Cadet Parking Lot SITE WATER UTILITY Section 33 11 16 K ...

.8 ANSI/AWWA C651-05, Disinfecting Water Mains. .9 ANSI/AWWA C900-07, Polyvinyl Chloride (PVC) Pressure Pipe, and Fabricated Fittings, 4 Inch through 12 Inch (100 mm - 300 mm), for Water Transmission and Distribution.

http://dalcon.ca/tenders/jobs/12-189-CadetParkingLotExpansion-Phasell/Specs/ES331116.PDF

Date added: August 13, 2013 - Views: 2

pdf
NORTH MARIN WATER DISTRICT STANDARD SPECIFICATIONS SECTION ...

AWWA C651 - Disinfecting Water Mains . 1.03 RELATED WORK SPECIFIED ELSEWHERE. AWWA Standard Methods for the Examination of Water and Waste Water . NMWD Standard Specifications 15000, 15044, 15056, ... 3.05 BACTERIOLOGICAL TESTING.

http://www.nmwd.com/pdf/waterdesignconstructionstandards/Std%20Spec%20Section%2015041%20Disinfectio%20of%20Piping.pdf

Date added: May 31, 2012 - Views: 11

pdf
SECTION 33 05 05 - Paulding County, Georgia

CT053378 33 05 05-1 SECTION 33 05 05 . BURIED PIPING INSTALLATION . PART 1 - GENERAL 1.1 DESCRIPTION A. Scope: ... ANSI/AWWA C651, Disinfecting Water Mains. 11. AWWA M23, PVC Pipe - Design and Installation. 12. AWWA M41, Ductile-Iron Pipe and Fittings.

http://www.paulding.gov/DocumentCenter/Home/View/1324

Date added: December 14, 2013 - Views: 1

pdf
DISINFECTION OF DOMESTIC WATER SYSTEMS PART 1 GENERAL

A. AWWA Standards C651, C652 and C659. 1.04 QUALITY ASSURANCE A. Regulatory Agency Requirements: Comply with applicable state requirements. 1.05 SUBMITTALS A. Disinfection Program; submit the following to be used during the program: 1. Cleaning ...

http://virtual.cocef.org/US_stu/USstu19/technical_specs/02715_DisinfOfWater.pdf

Date added: August 1, 2013 - Views: 15

pdf
W1 Ductile Iron Pipe and Fittings - Pflugerville, Texas

B. American Water Works Association (AWWA) 1. AWWA C104 ... 9. AWWA C651 - Disinfection Water Mains C. American National Standards Institute (ANSI) 1. ... W1.05 MATERIALS A. Ductile iron pipe shall conform to AWWA C151, ...

http://www.pflugervilletx.gov/documents/114/321/Water_Wastewater_Concrete_201301020932265528.pdf

Date added: May 9, 2013 - Views: 11

pdf
SECTION SYSTEMS DISINFECTION AND VOC TESTING

C651 AWWA Standard for Disinfecting Water Mains 2. C652 AWWA Standard for Disinfecting Tanks 3. ... 3.05 PROTECTION OF DISINFECTED STRUCTURES A. If required to re-enter a disinfected structure, the work shall be conducted utilizing

http://staffrep.ci.ceres.ca.us/RFP/Well22/Part%2007%20Well%20Construction%20Documents%20and%20Specifications/Section%2010%20Valves,%20Piping,%20Appurtenances,%20and%20Disinfection/11201-System%20Disinfection.pdf

Date added: November 10, 2013 - Views: 1

pdf
SECTION 02519 DISINFECTION OF WATER SYSTEMS PART 1 GENERAL

American Water Works Association (AWWA): a. B300, Hypochlorites. b. ... A. Conform to AWWA C651 for pipes and pipelines, except as modified in these Specifications, ... 3.05 TESTING A. Collection of Samples: 1.

http://virtual.cocef.org/Discos_documentos_consultores/Disco_324/Specifications/02519_Disinfection_Water_Systems.pdf

Date added: June 20, 2014 - Views: 1

pdf
SECTION 02071 GEOTEXTILE FABRICS This Section covers ...

AWWA C651 Disinfecting Water Mains 1.05 SUBMITTALS: IN ACCORDANCE WITH REQUIREMENTS OF GENERAL SPECIFICATIONS, SUBMIT THE FOLLOWING: A. Six sets of all shop drawings shall be submitted to the Engineer for review. B. Shop ...

http://www.haynesconstruction.com/Wilton%20Commons/specs/Div%202%20Sitework.pdf

Date added: July 30, 2013 - Views: 2

pdf
QUESTION AND ANSWER REFERENCES - San Francisco Public ...

AWWA (2005b) Standard for Disinfecting Water Mains, ANSI/AWWA C651-05. AWWA (2006a), Fundamentals and Control of Nitrification in Chloraminated Drinking Water Distribution Systems, Manual of Water Supply Practices – M56, American Water Works

http://www.sfwater.org/modules/showdocument.aspx?documentid=952

Date added: May 21, 2013 - Views: 1

pdf
SECTION 15200 DISINFECTION OF WATER PROCESS AND DISTRIBUTION ...

Disinfecting Water Mains AWWA C651 2. Hypochlorites AWWA B300 3. Liquid Chlorine AWWA B301 1.03 SUBMITTALS A. Test Reports 1. The Contractor shall submit disinfection reports which include the following information: ... 3.05 POINT OF APPLICATION A.

http://www.casselberry.org/documents/217/219/539/Disinfection_201311211526168740.pdf

Date added: January 8, 2014 - Views: 3

pdf
SECTION 02660 WATER DISTRIBUTION SYSTEMS PART 1 GENERAL A ...

05-062/03-10 (Water Distribution Systems) 02660-2 7. AWWA C550, Standard for Protective Epoxy Interior Coatings ... AWWA C600, Standard for Installation of Ductile-Iron Water Mains and Their Appurtenances. 9. AWWA C651, Standard for Disinfecting Water Mains. 1.04 DELIVERY, STORAGE, AND ...

http://www.cityofjeffersonga.com/sitebuildercontent/sitebuilderfiles/sec02660.pdf

Date added: August 8, 2013 - Views: 5

pdf
QUESTION AND ANSWER REFERENCES - San Francisco Public ...

AWWA (2005b) Standard for Disinfecting Water Mains, ANSI/AWWA C651-05. AWWA (2006a), Fundamental s and Control of Nitrification in Chloraminated Drinking Water Distribution Systems, Manual of Water Supply Practices – M56, American Water Works

http://www.sfwater.org/modules/showdocument.aspx?documentid=4163

Date added: August 31, 2013 - Views: 3

pdf
ITEM 660.5XM TEMPORARY BYPASS PIPING DESCRIPTION

ITEM 660.5XM TEMPORARY BYPASS PIPING 660-5XM.doc 3 of 9 Last Revised 1-05 lbs.) of high performance asphalt material. Disinfection Chemicals: ANSI/AWWA B300 – Sodium Hypochlorite.

http://www.monroecounty.gov/p/specs/5908.pdf

Date added: May 15, 2012 - Views: 3

pdf
Effective Microbial Control Strategies for Main Breaks and ...

parts of AWWA Standard C651 or U.K. Technical Guidance Notes 12. Issues What Was Found? ... Microsoft PowerPoint - 5. 1300_2014-05-06 PNWS-AWWA Kwan.pptx Author: lbanks Created Date: 6/3/2014 11:17:50 AM ...

http://www.pnws-awwa.org/uploads/PDFs/conferences/2014/5.%201300_2014-05-06%20PNWS-AWWA%20Kwan.pdf

Date added: June 30, 2014 - Views: 1

pdf
Approved by Board of Directors MOULTON NIGUEL WATER DISTRICT

After chlorination, the water shall be flushed from the line, in accordance with AWWA C651, at its extremities until the replacement water tests are equal chemically and bacteriologically to those of the permanent source of supply.

http://mnwd.com/wp-content/uploads/2013/05/15041-Chlorination-of-Domestic-Water-Mains-and-Services-for-Disinfections.pdf

Date added: September 25, 2013 - Views: 5