Use of buried pipes for energy conservation in cooling of agricultural greenhouses

This document was uploaded by one of our users. The uploader already confirmed that they had the permission to publish it. If you are author/publisher or own the copyright of this documents, please report to us by using this DMCA report form.

Simply click on the Download Book button.

Yes, Book downloads on Ebookily are 100% Free.

Sometimes the book is free on Amazon As well, so go ahead and hit "Search on Amazon"

Solar Energy. – 1995. – 55(2). – P. 111–124.
Earth-to-air heat exchangers can be used for energy conservation in cooling of agricultural
greenhouses. A parametric analysis performed for a typical glass greenhouse illustrates the effect of pipe length, pipe diameter, and air velocity inside the pipes on the performance of the system. Measured data of indoor air temperature collected from a 1000 m2 fiberglass covered greenhouse, equipped with four buried pipes, are compared with calculated data and are found to be in very good agreement.

Author(s): Santamouris M., Mihalakakou G., Balaras C.A., Argiriou A., Asimakopoulos D., Vallindras M.