Ieee Std c37.101-1993

This document was uploaded by one of our users. The uploader already confirmed that they had the permission to publish it. If you are author/publisher or own the copyright of this documents, please report to us by using this DMCA report form.

Simply click on the Download Book button.

Yes, Book downloads on Ebookily are 100% Free.

Sometimes the book is free on Amazon As well, so go ahead and hit "Search on Amazon"

Author(s): IEEE
Series: Ieee Guide For Generator Ground Protection
Publisher: Institute of Electrical & Electronics Enginee

Language: English
Pages: 59

Title Page......Page 1
Introduction......Page 3
Participants......Page 4
CONTENTS......Page 6
1.2 Description of the guide......Page 8
3. Summary of protection schemes......Page 9
4. Generator connections......Page 11
5.1 Method I: High-resistance grounded (distribution-transformer grounded)......Page 13
5.5 Method V: Resonant grounded (ground-fault neutralizer grounded {GFN])......Page 14
6. Protective schemes......Page 15
6.1 Scheme 1: Ground overvoltage—Complete shutdown......Page 16
6.2 Scheme 2: Ground overvoltage—Permissive shutdown......Page 18
6.4 Scheme 4: Ground overvoltage—Alarm......Page 19
6.5 Scheme 5: Start-up ground overvoltage—Complete shutdown......Page 20
6.6 Scheme 6: Ground-fault neutralizer overvoltage—Alarm and time-delay orderly shutdown......Page 21
6.7 Scheme 7: Wye-broken-delta voltage transformer (vt) ground overvoltage—Complete shutdown......Page 23
6.9 Scheme 9: Secondary-connected current transformer (ct), time-delay ground overcurrent—Complete shutdown......Page 24
6.10 Scheme 10: Primary connected ct, time-delay ground overcurrent—Complete shutdown......Page 25
6.11 Scheme 11: Instantaneous ground overcurrent—Alarm and/or complete shutdown......Page 26
6.12 Scheme 12: Generator leads ground overcurrent—Complete shutdown......Page 27
6.13 Scheme 13: Three-wire generator leads window ct instantaneous ground overcurrent—Complete shutdown......Page 28
6.15 Scheme 15: Generator percentage differential—Complete shutdown......Page 29
6.16 Scheme 16: Generator ground differential using product type relay......Page 30
6.18 Scheme 18: Ground-fault relays for the complete protection of the generator stator winding......Page 31
6.19 Scheme 19: Alternate stator winding protection using high-impedance differential relays......Page 36
6.20 Scheme 20: Generator neutral overcurrent protection for the case of accidental solid neutral grounding......Page 37
7. Protective device function numbers......Page 40
Annex A—Ground protection example for a high-resistance grounded generator......Page 42
Annex B—Ground protection example to determine the percent coverage of a high-impedance differential relay......Page 54
Annex C—Bibliography......Page 57