Iec 60250 pdfs

Searching:
Download
Iec 60250 - Fast Download

Download Iec 60250 from our fatest mirror

IEC and ISO - Doble Engineering

4916 dl's @ 8586 KB/s

pdf
IEC and ISO - Doble Engineering

IEC 60250: Relative permittivity, and dielectric dis-sipation factor of insulating materials IEC 60296: All specification tests including appearance IEC 60422: Oil to Oil Compatibility IEC 60450: Degree of polymerization and water of paper

http://www.doble.com/files.php?file=iec_iso_brocure_03-08.pdf

Date added: October 22, 2011 - Views: 330

pdf
Acetron MD (Product Data Sheet) - Engineering plastics, high ...

Dielectric dissipation factor tan δ: - at 1 MHz + IEC 60250 - - ++ IEC 60250 - - Comparative tracking index (CTI) + IEC 60112 - - ++ IEC 60112 - - Note: 1 g/cm³ = 1,000 kg/m³ ; 1 MPa = 1 N/mm² ; 1 kV/mm = 1 MV/m.

http://www.quadrantplastics.com/fileadmin/quadrant/documents/QEPP/EU/Product_Data_Sheets_PDF/GEP/Acetron_MD_PDS_E_04282014.pdf

Date added: June 6, 2014 - Views: 1

pdf
>> POLYAMIDE [PA 66] ERTALON 66 SA - Engineering plastics ...

Relative permittivity εr: - at 1 MHz + IEC 60250 - 3.3 ++ IEC 60250 - 3.8 Dielectric dissipation factor tan δ: - at 100 Hz + IEC 60250 - 0.013 ++ IEC 60250 - 0.13 Dielectric dissipation factor tan δ: - at 1 MHz + IEC 60250 - 0.020

http://www.quadrantplastics.com/fileadmin/quadrant/documents/QEPP/EU/Product_Data_Sheets_PDF/GEP/Ertalon_66_SA_PDS_E_25012011.pdf

Date added: October 26, 2013 - Views: 1

pdf
IEC and ISO Test Methods - Doble Engineering

IEC 60250: Relative permittivity, and dielectric dissipation factor of insulating materials IEC 60296: Appearance IEC 60422: Oil to Oil Compatibility IEC 60450: Degree of polymerization and water of paper IEC 60554-2: Test methods for cellulosic papers

http://www.doble.com/content/services/IEC%20&%20ISO%20Test%20Methods%20Brochure.PDF

Date added: February 1, 2012 - Views: 529

pdf
Product Information Ultramid B27 E 01

Dielectric Constant (100 Hz) IEC 60250 4 - Dielectric Constant (1 MHz) IEC 60250 3.5 7 Dissipation Factor (100 Hz) IEC 60250 100 - Dissipation Factor (1 MHz) IEC 60250 230 3,000 ...

http://iwww.plasticsportal.com/products/dspdf.php?type=iso¶m=Ultramid+B27+E+01

Date added: February 2, 2013 - Views: 3

pdf
practical experience Melt mass-flow rate 300 °C; 1.2 kg g/10 ...

C Relative permittivity 100 Hz - IEC 60250 3.1 C Relative permittivity 1 MHz - IEC 60250 3.0 C Dissipation factor 100 Hz 10-4 IEC 60250 5 C Dissipation factor 1 MHz 10-4 IEC 60250 90 C Volume resistivity Ohm·m IEC 60093 1E14 C Surface resistivity Ohm IEC 60093 1E16

http://www.urviplastic.com/pdf/2407.pdf

Date added: June 10, 2013 - Views: 22

pdf
Polycarbonate-ABS Blend (PC-ABS) - Applied Rapid Technologies

IEC 60250 IEC 60250 205° F 230° F 234° F 4.10E-5 in/in F 257° F Not Applicable2 1.20 0.0397 lb/in^3 HB 0.85mm R110 35 3.1 3.0 96° C 110° C 112° C 125° C Not Applicable2 1.20 1.1 gr/cm^3 HB 0.85mm R110 35 3.1 3.0 Other Test Method Value APPEARANCE zBlack SYSTEM AVAILABILITY

http://www.artcorp.com/pdf/PCABS.pdf

Date added: September 26, 2013 - Views: 1

pdf
INTERNATIONAL STANDARD NORME INTERNATIONALE

IEC 60250:1969, Recommended methods for the determination of the permittivity and dielectric dissipation factor of electrical insulating materials at power, audio and radio frequencies including metre wavelengths

http://webstore.iec.ch/preview/info_iec62631-1%7Bed1.0%7Db.pdf

Date added: March 4, 2013 - Views: 146

pdf
Edition 2.0 TECHNICAL SPECIFICATION - IEC Webstore | Welcome

IEC 60250, Recommended methods for the determination of the permittivity and dielectric dissipation factor of electrical insulating materials at power, audio and radio frequencies including metre wavelengths

http://webstore.iec.ch/preview/info_iec62332-1%7Bed2.0%7Den.pdf

Date added: May 10, 2012 - Views: 31

pdf
Akulon K224-G6 - Arian Terminal Web Site

Relative permittivity (100Hz) 3.5 / 20 - IEC 60250 Relative permittivity (1 MHz) 3.3 / 5 - IEC 60250 Dissipation factor (100 Hz) 50 / 3000 E-4 IEC 60250 Dissipation factor (1 MHz) 150 / 1200 E-4 IEC 60250 Volume resistivity 1E13 / 1E11 Ohm*m IEC 60093

http://www.at-ir.com/engineering/product/DSM-EP-DataSheet/en%20data%20sheet%201-100/40.pdf

Date added: January 27, 2013 - Views: 2

pdf
HOSTAFORM® C 9021 | POM | Unfilled - b2bPolymers.com

Relative permittivity - 1 MHz 4 - IEC 60250 Dissipation factor - 100 Hz 20 E-4 IEC 60250 Dissipation factor - 1 MHz 50 E-4 IEC 60250 Volume resistivity 1E12 Ohm*m IEC 60093 Surface resistivity 1E14 Ohm IEC 60093 Electric strength 35 kV/mm IEC 60243-1

http://www.b2bpolymers.com/TDS/Ticona_Hostaform_C9021.pdf

Date added: May 20, 2014 - Views: 1

pdf
Product Information Luran S - PromaPlast

Dissipation factor (100 Hz) IEC 60250 E-4 60 Dissipation factor (1 MHz) IEC 60250 E-4 100 Volume resistivity IEC 60093 Ohm*m 1E13 Surface resisitivity IEC 60093 Ohm 1E14 Electric strength K20/K20 IEC 60243-1 kV/mm 38 Comparative tracking index, CTI, test liquid A IEC 60112 - 225

http://www.promaplast.com/uploads/Luran%20S%20KR%202863%20C.pdf

Date added: January 1, 2014 - Views: 2

pdf
Lexan* Exell* D Sheet Product Datasheet Description Typical ...

Relative Permittivity 50/60Hz IEC 60250 - 2.7 Relative Permittivity 1Mhz IEC 60250 - 2.7 Dissipation Factor 50/60 Hz IEC 60250 - 0.001 Dissipation Factor 1Mhz IEC 60250 - 0.01 Arc Resistance Tungsten ASTM-D495 sec. 119 Optical Light ...

http://www.sabic-ip.com/resins/DataSheet/Internet/PDF/1002002135_1002003989_1002038193_SI.pdf

Date added: June 18, 2012 - Views: 3

pdf
>> ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE [PE-UHMW ...

Relative permittivity εr: - at 1 MHz IEC 60250 - 3.0 Dielectric dissipation factor tan δ: - at 100 Hz IEC 60250 - 0.0004 Dielectric dissipation factor tan δ: - at 1 MHz IEC 60250 - 0.0010 Comparative tracking index (CTI) IEC 60112 - 600

http://www.professionalplastics.com/professionalplastics/Tivar_DS_DataSheet.pdf

Date added: October 23, 2012 - Views: 11

pdf
Product Information Luran S - PromaPlast

Relative permittivity (1 MHz) IEC 60250 - 3 Dissipation factor (100 Hz) IEC 60250 E-4 60 Dissipation factor (1 MHz) IEC 60250 E-4 100 Volume resistivity IEC 60093 Ohm*m 1E13 Surface resisitivity IEC 60093 Ohm 1E14 Comparative tracking index, CTI, test liquid A IEC 60112 - 250

http://www.promaplast.com/uploads/Luran%20S%20KR%202867%20C%20WU.pdf

Date added: March 12, 2013 - Views: 1

pdf
Lexan FR60 film datasheet -SABIC-10052011

IEC 60243 IEC 60250 IEC 60250 IEC 60250 IEC 60250 IEC 60093 IEC 60093 Units (USCS) kV/mm Ω-cm

http://www.sabic-ip.com/resins/DataSheet/Internet/PDF/1002002131_1002003939_1002038228_SI.pdf

Date added: January 12, 2014 - Views: 2

pdf
>> POLYACETAL [POM-C] ERTACETAL C - Plastic Stockist

Relative permittivity εr: - at 1 MHz + IEC 60250 - 3.8 ++ IEC 60250 - 3.8 Dielectric dissipation factor tan δ: - at 100 Hz + IEC 60250 - 0.003 ++ IEC 60250 - 0.003 Dielectric dissipation factor tan δ: - at 1 MHz + IEC 60250 - 0.008

http://www.plasticstockist.com/downloads/datasheets/acetal_c.pdf

Date added: September 6, 2013 - Views: 6

pdf
PDF created with pdfFactory trial version www.pdffactory

PDF created with pdfFactory trial version www.pdffactory.com. IEC60965-2-1 60250 TEC 60243-1 8.2.2.4.1 82.1 IEC 60093 — DAP-PC-3893.00

http://www.eiseco.com/wp-content/uploads/2013/12/EISECO.-GRP-Fuse-Box-Test-Reports-According-to-IEC60093-IEC60965-2-1-IEC60250-IEC60243-1.pdf

Date added: March 19, 2014 - Views: 1

pdf
Technical Data Sheet ECCOBOND 45LV/Catalyst 15LV

TDS ECCOBOND 45LV/Catalyst 15LV, April-2010 Electrical Properties: Dielectric Breakdown Strength, IEC 60243-1, kV/mm 16 Dielectric Constant / Dissipation Factor, IEC 60250:

http://krayden.com/tds/henk_eccobond_45lv_tds.pdf

Date added: September 26, 2012 - Views: 7

pdf
Product Information Ultramid B3K - Product Locator - BASF ...

Volume Resistivity IEC 60093 1E13 1E10 Dielectric Constant (100 Hz) IEC 60250 4 - Dielectric Constant (1 MHz) IEC 60250 3.5 7 Dissipation Factor (100 Hz) IEC 60250 100 -

http://iwww.plasticsportal.com/products/dspdf.php?type=iso¶m=Ultramid+B3K

Date added: October 18, 2012 - Views: 2

pdf
PurePolycarbonate® General Purpose Sheet Grade

PurePolycarbonate® General Purpose Sheet Grade Property Unit Test Method Value Electrical Specific Inductive Capacity 100 Hz - IEC 60250 3.1

http://highlinepc.com/wp-content/uploads/2013/02/Brochure-General-Purpose-Sheet.pdf

Date added: September 6, 2013 - Views: 4

pdf
RoHS 3 Scotchcast™ Electrical Insulating Resin 1402FR

Electrical Properties after wet ageing Volume resistivity at 23 °C > 1,0E+14 Ωcm IEC 60250 Dielectric Strength at 23 °C > 20 kV/mm EN 60243-1

http://multimedia.3m.com/mws/mediawebserver?mwsId=66666UF6EVsSyXTtOXTVn8TyEVtQEVs6EVs6EVs6E666666--&fn=1402FR.pdf

Date added: May 6, 2013 - Views: 1

pdf
Bayblend T85 ISO - VistaTek

C Relative permittivity 1 MHz - IEC 60250 3.0 C Dissipation factor 100 Hz 10-4 IEC 60250 20 C Dissipation factor 1 MHz 10-4 IEC 60250 85 C Volume resistivity Ohm·m IEC 60093 1E14 C Surface resistivity Ohm IEC 60093 1E16 C Electrical strength 1 mm kV/mm IEC 60243-1 35

http://www.vistatek.com/pdfs/Bayblend_T85_ISO.pdf

Date added: April 15, 2012 - Views: 23

pdf
>> POLYACETAL [POM-H] ERTACETAL H - Plastic Stockist

Relative permittivity εr: - at 1 MHz + IEC 60250 - 3.8 ++ IEC 60250 - 3.8 Dielectric dissipation factor tan δ: - at 100 Hz + IEC 60250 - 0.003 ++ IEC 60250 - 0.003 Dielectric dissipation factor tan δ: - at 1 MHz + IEC 60250 - 0.008

http://www.plasticstockist.com/downloads/datasheets/acetal_h.pdf

Date added: May 28, 2013 - Views: 8

pdf
Catalogue - gdhongyue.com

Dielectric dissipation factor (1kHz) IEC 60250 - Dielectric dissipation factor (1MHz) IEC 60250 - Tracking resistance (CTI) V IEC 60112 - Flammability UL94 - The yellow card File No. - Appropriate List number of Ministerial Ordinance for Export Trade Control Item 16 of Appendix -1

http://www.gdhongyue.com/uploadfile/2010714145240584.pdf

Date added: October 18, 2013 - Views: 1

pdf
>> ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE [PE-UHMW + micro ...

Relative permittivity εr: - at 1 MHz IEC 60250 - - Dielectric dissipation factor tan δ: - at 100 Hz IEC 60250 - - Dielectric dissipation factor tan δ: - at 1 MHz IEC 60250 - - Comparative tracking index (CTI) IEC 60112 - -

http://www.professionalplastics.com/professionalplastics/Tivar_CeramP_DataSheet.pdf

Date added: September 26, 2012 - Views: 4

pdf
REACH Scotchcast Resin N°1402FR Electrical Insulating Resin

IEC 60250 Dielectric Strength at 23 °C > 20 kV/mm EN 60243-1 Dielectric constant at 23 °C <6 IEC 60250 Flame retardant properties Property Value Specification Flammability V0 (3mm) UL94 Content of halogen <0,5 % EN 5067-2-1

http://multimedia.3m.com/mws/mediawebserver?mwsId=SSSSSufSevTsZxtUo8_vlx2UevUqevTSevTSevTSeSSSSSS--&fn=Datasheet%20SC%201402FR.pdf

Date added: December 10, 2013 - Views: 4

pdf
VECTRA® A115 | LCP | Glass Reinforced - Craftech Ind

Relative permittivity - 1 MHz 3 - IEC 60250 Dissipation factor - 100 Hz 200 E-4 IEC 60250 Dissipation factor - 1 MHz 180 E-4 IEC 60250 Volume resistivity 1E13 Ohm*m IEC 60093 Surface resistivity >1E15 Ohm IEC 60093 Electric strength 34 kV/mm IEC 60243-1

http://www.craftechind.com/assets/Vectra-LCP_Ticona.pdf

Date added: July 11, 2013 - Views: 5

pdf
Resin p Rate (3.2z:zt. Yield at at impact propertie (CTI ...

Resin p Rate (3.2z:zt. Yield at at impact propertie (CTI) Test M od ISO Iso ISO 527-2 ISO 179-1 179-2 Iso 75-1 , ISO UL94 IEc 60250 IEc '0250

http://www.kamdarplastics.com/other-files/6.pdf

Date added: February 20, 2014 - Views: 4

pdf
VICTREX PEEK 381G

Loss Tangent 23°C, 1MHz IEC 60250 n/a 0.003 Dielectric Constant 23°C, 50Hz IEC 60250 n/a 3.2 200°C, 50Hz 4.5 Volume Resistivity 23°C IEC 60093 Ω cm 1016 * 125°C 1015 * 275°C 109 * Fire Smoke Toxicity Glow Wire Test 2mm ...

http://www.victrex.com/docs/datasheets-docs/Victrex_TDS_381G.pdf

Date added: February 20, 2013 - Views: 4

pdf
>> POLYAMIDE [PA 6 + oil] NYLATRON LFG - Professional Plastics

Relative permittivity εr: - at 1 MHz + IEC 60250 - 3.1 ++ IEC 60250 - 3.6 Dielectric dissipation factor tan δ: - at 100 Hz + IEC 60250 - 0.015 ++ IEC 60250 - 0.15 Dielectric dissipation factor tan δ: - at 1 MHz + IEC 60250 - 0.016

http://www.professionalplastics.com/professionalplastics/NylatronLFG_DataSheet.pdf

Date added: April 23, 2012 - Views: 23

pdf
Technical data sheet - IngePlastic

Dielectric constant IEC 60250 - Dielectric dissipation factor (50Hz) IEC 60250 - Volume resistivity IEC 60093 Ω *cm - Surface resistivity IEC 60093 Ω 1016 Comparative tracking index IEC 60112 - Dielectric strength IEC 60243 kV/mm 20 The short-term ...

http://www.ingeplastic.com/web/webimg/Datasheet-SUSTAPEEK-GLD-140-natural-EN[1].pdf

Date added: September 17, 2013 - Views: 3

pdf
>> POLYAMIDE [PA 66] ERTALON 66 SA - Metales Industriales

Relative permittivity εr: - at 1 MHz + IEC 60250 - 3.3 ++ IEC 60250 - 3.8 Dielectric dissipation factor tan δ: - at 100 Hz + IEC 60250 - 0.013 ++ IEC 60250 - 0.13 Dielectric dissipation factor tan δ: - at 1 MHz + IEC 60250 - 0.020

http://www.metalesindustriales.com/media/File/ertalon66.pdf

Date added: February 11, 2012 - Views: 5

pdf
TECHNYL® A 20 V25 NATURAL - Southland Polymers

Relative permittivity IEC 60250 3.40 4 Dissipation factor IEC 60250 0.02 0.05 Volume resistivity IEC 60093 E14.Ohm.cm 10 0.100000 Surface resistivity IEC 60093 E14.Ohm 0.100000 0.010000 Dielectric strength IEC 60243 kV/mm 25 25 Comparative tracking index sol.

http://www.southlandpolymers.com/pdf/nylon/a20v25.pdf

Date added: December 23, 2013 - Views: 2

pdf
HOSTAFORM® C 9021 M XAP²™ | POM | Tribological

Relative permittivity - 1 MHz 4.2 - IEC 60250 Dissipation factor - 100 Hz 25 E-4 IEC 60250 Dissipation factor - 1 MHz 80 E-4 IEC 60250 Volume resistivity 1E12 Ohm*m IEC 60093. HOSTAFORM® C 9021 M XAP²™ | POM | Tribological Ticona - A business of Celanese

http://www.eurotecsrl.info/pdf/HOSTAFORM-C9021M-XAP.pdf

Date added: June 4, 2014 - Views: 1

pdf
CELANEX ® 3300 -2 | PBT | Glass Reinforced

Relative permittivity - 100 Hz 4.5 - IEC 60250 Relative permittivity - 1 MHz 4.1 - IEC 60250 Dissipation factor - 100 Hz 22 E-4 IEC 60250 Dissipation factor - 1 MHz 160 E-4 IEC 60250 Volume resistivity >1E13 Ohm*m IEC 60093 Surface resistivity >1E15 Ohm IEC 60093

http://www.hipolymers.com.ar/pdfs/celanex/datos/Celanex/celanex%203300-2.pdf

Date added: June 4, 2012 - Views: 5

pdf
Product Information Terluran - Петробул БГ

Relative permittivity (100Hz) IEC 60250 - 2.9 Relative permittivity (1 MHz) IEC 60250 - 2.8 Dissipation factor (100 Hz) IEC 60250 E-4 48 Dissipation factor (1 MHz) IEC 60250 E-4 79 Volume resistivity IEC 60093 Ohm*m 1E13 Surface resistivity IEC 60093 Ohm 1E13

http://www.petrobul-bg.com/files/Terluran_GP_22.pdf

Date added: March 2, 2012 - Views: 9

pdf
CELANEX® 3316 | PBT | Glass Reinforced - Hi Polymers

Relative permittivity - 100 Hz 4 - IEC 60250 Relative permittivity - 1 MHz 3.6 - IEC 60250 Dissipation factor - 100 Hz 33 E-4 IEC 60250 Dissipation factor - 1 MHz 145 E-4 IEC 60250 Volume resistivity 1E13 Ohm*m IEC 60093 Surface resistivity 1E15 Ohm IEC 60093.

http://www.hipolymers.com.ar/pdfs/celanex/datos/Celanex/celanex%203316.pdf

Date added: October 11, 2012 - Views: 3

pdf
VECTRA C130 - Data Sheet - Mill-Max Mfg. Corp.

Relative permittivity - 1MHz IEC 60250 3.7 Dissipation factor - 100Hz IEC 60250 140 E-4 Dissipation factor - 1MHz IEC 60250 180 E-4 Volume resistivity IEC 60093 1E13 ohm-m Surface resistivity IEC 60093 >1E15 ohm Electric strength IEC 60243-1 35 KV/mm Comparative ...

http://www.mill-max.com/assets/tech/pdf/vectra.pdf

Date added: September 1, 2013 - Views: 7

pdf
FORTRONGeneral Properties(ISO) - gdhongyue.com

Dielectric constant (1MHz) IEC 60250 5.4 Dielectric dissipation factor (1kHz) IEC 60250 0.001 Dielectric dissipation factor (1MHz) IEC 60250 0.002 Tracking resistance (CTI) V IEC 60112 175 Flammability UL94 V-0 The yellow card File No. E109088

http://www.gdhongyue.com/uploadfile/201071411215644.pdf

Date added: May 5, 2013 - Views: 11

pdf
Product Information Ultramid® A3k - Value Plastics, A ...

Volume Resistivity IEC 60093 1E13 Surface Resistivity IEC 60093 1E13 Dielectric Constant (100 Hz) IEC 60250 3.8 Dielectric Constant (1 MHz) IEC 60250 3.2

http://www.valueplastics.com/technical/material/Nylon/Ultramid%20A3K%20Nylon%20Material%20Data.pdf

Date added: February 1, 2012 - Views: 15

pdf
GB-Bectron PL 4122 E BLF - Plasma Ruggedized Solutions

Permittivity 3,5 - Beck Test 3b, based on IEC 60250 23 °C, 10 kHz Volume resistivity 1·10 15 cm Beck Test 5, based on IEC 60464 part 2 - after 7 d water immersion 1·10 15 cm 23 °C Dielectric strength 112 kV/mm Beck Test 6a/6b based on IEC 60464, part 2

http://www.plasmarugged.com/uploads/pdfs/Bectron_PL4122_TDS.PDF

Date added: September 26, 2012 - Views: 2

pdf
Lexan* EFR95-701 Film Product Datasheet - Regal Graphics

@ 1 MHz ASTM D150 - 0.01 IEC 60250 - 0.01 Volume Resistivity ASTM D257 -cm 1.17E+16 IEC 60093 -cm 1.17E+16 Surface Resistivity ASTM D257 /square 4.4E+15 IEC 60093 /square 4.4E+15 Arc Resistance, Tungsten Electrodes ASTM D495 s 51

http://regalgraphics.com/datasheet/Lexan_EFR95-701_Film_Datasheet.pdf

Date added: February 1, 2013 - Views: 2

pdf
GUR® 4152 | PE-UHMW | Unfilled - Eurotec srl

Relative permittivity - 1 MHz 3 - IEC 60250 Dissipation factor - 100 Hz 4 E-4 IEC 60250 Dissipation factor - 1 MHz 10 E-4 IEC 60250 Volume resistivity >1E12 Ohm*m IEC 60093 Surface resistivity >1E12 Ohm IEC 60093 Electric strength 45 kV/mm IEC 60243-1

http://www.eurotecsrl.info/pdf/GUR4152.pdf

Date added: October 28, 2013 - Views: 1

pdf
Product Information LEXAN - JIT Components

Relative Permittivity, 1 MHz 2.7 - IEC 60250 Dissipation Factor, 50 Hz 0.0010 - IEC 60250 Dissipation Factor, 1 MHz 0.0100 - IEC 60250 Comparative Tracking ...

http://www.jit-components.com/information/943.pdf

Date added: May 6, 2013 - Views: 2

pdf
644Z - AKchem.com

IEC 60250 Mechanical Electrical IEC 60250 Dielectric Constant Dissipation Factor Physical Thermal Temperature of Deflection Under Load(DTUL) oC Modified Polyphenylene Ether Resin Non-Reinforced, Flame Retardant Grade 644Z. Author: 旭化成グループ

http://www.akchem.com/rs/eng/contentsfiles/emt/etc/xyron/bussei_xyron_644Z_eng_2.pdf

Date added: April 22, 2012 - Views: 8

pdf
VICTREX PEEK 90GL60

Loss Tangent 23°C, 1 MHz IEC 60250 n/a 0.004 Dielectric Constant 23°C, 1 kHz IEC 60250 n/a 3.8 Volume Resistivity IEC 60093 Ω cm 1016 * Fire Smoke Toxicity Glow Wire Test 2mm thickness IEC 60695-2-12 ºC 960 * Result based on similar products Recommended ...

http://www.victrex.com/docs/datasheets-docs/Victrex_TDS_90GL60.pdf

Date added: December 17, 2013 - Views: 1

pdf
Product Range (Europe) - PlasticsPortal

Dielectric constant at 1MHz – IEC 60250 dry/ cond. 3.2 /5 3.2 /5 3.1/3.6 3.2 /5 Dissipation factor at 1MHz 10 -4 IEC 60250 dry/ cond. 250 /2,000 250 / 2,000 160 / 700 250 / 2,000 Volume resistivity Ω·m IEC 60093 dry/ cond. 1013/1010 1013/109 4·10 12/1010 1013/1010

http://www.plasticsportal.net/wa/plasticsEU~en_GB/function/conversions:/publish/common/upload/engineering_plastics/Ultramid_range_chart.pdf

Date added: December 15, 2012 - Views: 4

pdf
Arnite T06 202 - Nevicolor

Dissipation factor (100 Hz) 20 E-4 IEC 60250 Dissipation factor (1 MHz) 200 E-4 IEC 60250 Volume resistivity >1E13 Ohm*m IEC 60093 Surface resistivity >1E15 Ohm IEC 60093 Electric strength 27 kV/mm IEC 60243-1 Comparative tracking index 600 - IEC 60112 OTHER PROPERTIES

http://www.nevicolor.com/images/commercializzati/pdf/arnite_pbt/Arnite_T06_202.pdf

Date added: January 17, 2014 - Views: 2

pdf
Product Data Sheet, July 2012 Vivak Solid copolyester sheet

Dielectric constant at 103 Hz 2.6 IEC 60250 6 at 10 Hz 2.4 IEC 60250 Dissipation factor at 103 Hz 0.005 IEC 60250 6 at 10 Hz 0.02 IEC 60250 Product Data Sheet, July 2012 Vivak® Solid copolyester sheet Vivak® is a ...

http://www.bayersheeteurope.com/index.php/fuseaction/download/lrn_file/mf0109_e_120715.pdf

Date added: May 28, 2013 - Views: 2