Intumescent Coating and Fire Protection of Steel Structures

This document was uploaded by one of our users. The uploader already confirmed that they had the permission to publish it. If you are author/publisher or own the copyright of this documents, please report to us by using this DMCA report form.

Simply click on the Download Book button.

Yes, Book downloads on Ebookily are 100% Free.

Sometimes the book is free on Amazon As well, so go ahead and hit "Search on Amazon"

Intumescent Coating and Fire Protection of Steel Structures establishes the thermo insulation characteristics of intumescent coating under various fire and hydrothermal aging circumstances and shows how to predict the temperature elevation of steel structures protected with intumescent coatings in fires for avoiding structural damage. Introduced are the features and applications of intumescent coatings for protecting steel structures against fire. The constant effective thermal conductivity is defined and employed to simplify the quantification for the thermo-resistance of intumescent coatings. An experimental investigation into the hydrothermal aging effects on insulative properties of intumescent coatings is presented, as well as the influence of topcoat on insulation and aging of intumescent coatings. Also described is a practical method for calculating the temperature of the protected steel structures with intumescent coatings in order to evaluate the fire safety of a structure. The book is aimed at fire and structural engineers, as well as researchers and students concerned with the protection of steel structures.

Author(s): Guo-Qiang Li, Ling-Ling Wang, Qing Xu, Jun-Wei Ge
Publisher: CRC Press
Year: 2023

Language: English
Pages: 159
City: Boca Raton

Cover
Half Title
Title Page
Copyright Page
Table of Contents
Authors
Chapter 1: Introduction to intumescent coatings
1.1 Damage of steel structures in fire
1.2 Types of insulative coatings for protecting steel structures against fire
1.2.1 Active fire protection and passive fire protection
1.2.2 Non-intumescent and intumescent types of fire insulation for steel structures
1.2.2.1 Non-intumescent coatings and boards
1.2.2.2 Intumescent coatings
1.3 Application of intumescent coatings for protecting steel structures
1.3.1 Advantages of intumescent coatings
1.3.2 Key points of application
1.3.2.1 Weather resistance
1.3.2.2 Using topcoats to improve water resistance
1.3.2.3 Fire protection of connections
1.3.2.4 Maintenance
1.3.3 Typical steel structure projects protected with intumescent coatings
1.3.3.1 Shanghai Tower building
1.3.3.2 Chengdu Tianfu New International Airport
1.3.3.3 Semiconductor manufacturing plants
1.4 Mechanism of intumescent coatings for fire protection of steel structures
1.5 Main issues of intumescent coatings for protecting steel structures
1.5.1 Determining the thermal resistance of intumescent coatings
1.5.2 Behaviour of intumescent coatings under large space fires
1.5.3 Behaviour of intumescent coatings under localized fires
1.5.4 Ageing effect of intumescent coatings
1.5.5 Influence of the topcoats on the fire protection of intumescent coatings
1.5.6 Temperature prediction of steel substrates protected by intumescent coatings
References
Chapter 2: Determining the thermal resistance of intumescent coatings
2.1 Definition and usage of the thermal conductivity of materials
2.2 Thermal conductivity of intumescent coatings
2.2.1 Time-dependent thermal conductivity
2.2.2 Effective thermal conductivity
2.2.3 Constant effective thermal conductivity
2.3 Tests for determining the constant effective thermal conductivity of intumescent coatings
2.3.1 Test specimens
2.3.2 Test setup
2.3.3 Test results and discussions
2.3.3.1 Furnace and steel temperatures
2.3.3.2 Effective thermal conductivity
2.3.3.3 Constant effective thermal conductivity
2.3.3.4 Comparison of constant effective thermal conductivity between various specimens
2.4 Use of constant effective thermal conductivities for intumescent coatings
2.5 Summary
References
Chapter 3: Behaviour of intumescent coatings under large space fires
3.1 Fire conditions
3.2 Test preparation
3.2.1 Test specimens
3.2.2 Fire protection
3.2.3 Test setup
3.3 Experimental measurements and observations of intumescent coating behaviour
3.4 The three-stage model of thermal conductivity
3.4.1 Temperature dependent effective thermal conductivity
3.4.2 Constant effective thermal conductivities
3.4.3 Inter-fire relationships for three-stage constant effective thermal conductivities
3.5 Applicability of the three-stage constant effective thermal conductivity model
3.5.1 Calculation of protected steel temperature with the three-stage thermal model
3.5.2 Effectiveness of the three-stage thermal conductivity model
3.6 Summary
References
Chapter 4: Behaviour of intumescent coatings exposed to localized fires
4.1 Localized fire and test setup
4.2 Test specimens
4.2.1 Steel members
4.2.2 Thermocouples
4.2.3 Fire protection
4.3 Observation of the localized fire
4.3.1 Flame
4.3.2 Fire temperature distributions
4.4 Performance of intumescent coatings
4.4.1 Reactions of intumescent coatings
4.4.2 Cracking of intumescent coatings
4.4.3 Expansion of intumescent coatings
4.4.4 Temperature-dependent effective thermal conductivity of intumescent coatings
4.4.5 Validation of three-stage model for the thermal resistance of intumescent coatings under localized fires
4.5 Summary
References
Chapter 5: Hydrothermal ageing effects on the insulative properties of intumescent coatings
5.1 Ageing mechanism of intumescent coatings in a hydrothermal environment
5.1.1 Test preparation
5.1.2 FTIR test results
5.1.3 XPS test results
5.2 Degradation of intumescent coatings due to ageing in a hydrothermal environment
5.2.1 Test specimens with intumescent coatings
5.2.2 Hydrothermal ageing tests
5.2.3 Fire tests
5.3 Assessment of insulative properties of aged intumescent coatings
5.3.1 Effect on the temperature elevation of steel substrates
5.3.2 Effect on the effective thermal conductivity of coatings
5.4 Summary
References
Chapter 6: Influence of topcoats on insulation and the anti-ageing performance of intumescent coatings
6.1 Effect of topcoats on restraining expansion and the thermal resistance of intumescent coatings
6.1.1 Specimen preparation
6.1.2 Fire tests
6.1.3 Test results
6.1.3.1 Appearance and expansion of intumescent coatings
6.1.3.2 Steel temperatures
6.1.3.3 Constant effective thermal conductivity
6.2 Effect of topcoats on the ageing of intumescent coatings
6.2.1 Specimen preparation
6.2.2 Hydrothermal ageing test
6.2.3 Fire test
6.2.3.1 Surface appearance of specimens
6.2.3.2 Microstructures of intumescent coating chars
6.2.3.3 Effect on expansion ratios
6.2.3.4 Effect on the temperature elevations of steel substrates
6.3 Summary
References
Chapter 7: Predicting the temperatures of steel substrates with intumescent coatings under non-uniform fire heating conditions
7.1 Steel temperature calculation method
7.2 Division of steel members exposed to non-uniform fire heating conditions
7.2.1 Division of steel members into segments
7.2.2 Division of a cross-section into plates
7.3 Gas temperature distribution of localized fires
7.4 Temperature distributions of steel members exposed to localized fires
7.4.1 Comparison of steel temperature distributions along member length
7.4.2 Comparison of steel temperature distributions across member section
7.4.3 Comparison of steel temperature–time curves
7.5 Summary
References
Index