IEC 61000-4-2: Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2:2008)

This document was uploaded by one of our users. The uploader already confirmed that they had the permission to publish it. If you are author/publisher or own the copyright of this documents, please report to us by using this DMCA report form.

Simply click on the Download Book button.

Yes, Book downloads on Ebookily are 100% Free.

Sometimes the book is free on Amazon As well, so go ahead and hit "Search on Amazon"

IEC 61000-4-2:2008 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and from personnel to adjacent objects. It additionally defines ranges of test levels which relate to different environmental and installation conditions and establishes test procedures. The object of IEC 61000-4-2:2008 is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which may occur frompersonnel to objects near vital equipment. IEC 61000-4-2:2008 defines typical waveform of the discharge current, range of test levels, test equipment, test setup, test procedure, calibration procedure and measurement uncertainty. IEC 61000-4-2:2008 gives specifications for test performed in "laboratories" and "post-installation tests" performed on equipment in the final installation. This second edition cancels and replaces the first edition published in 1995, its amendment 1 (1998) and its amendment 2 (2000) and constitutes a technical revision. It has the status of a basic EMC publication in accordance with IEC Guide 107. The main changes with respect to the first edition of this standard and its amendments are the following: - the specifications of the target have been extended up to 4 GHz. An example of target matching these requirements is also provided; - information on radiated fields from human-metal discharge and from ESD generators is provided; - measurement uncertainty considerations with examples of uncertainty budgets are given too.

Author(s): International Electrotechnical Commission
Edition: 2.0
Publisher: International Electrotechnical Commission
Year: 2008

Language: English

English
CONTENTS
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test levels
6 Test generator
6.1 General
6.2 Characteristics and performance of the ESD generator
6.3 Verification of the ESD setup
7 Test setup
7.1 Test equipment
7.2 Test setup for tests performed in laboratories
7.3 Test setup for post-installation tests
8 Test procedure
8.1 Laboratory reference conditions
8.2 EUT exercising
8.3 Execution of the test
9 Evaluation of test results
10 Test report
Annex A (informative) Explanatory notes
Annex B (normative) Calibration of the current measurement system and measurement of discharge current
Annex C (informative) Example of a calibration target meeting the requirements of Annex B
Annex D (informative) Radiated fields from human metal discharge and ESD generators
Annex E (informative) Measurement uncertainty (MU) considerations
Annex F (informative) Variation in test results and escalation strategy
Bibliography
Figures
Figure 1 – Simplified diagram of the ESD generator
Figure 2 – Ideal contact discharge current waveform at 4 kV
Figure 3 – Discharge electrodes of the ESD generator
Figure 4 – Example of test set-up for table-top equipment, laboratory tests
Figure 5 – Example of test setup for floor-standing equipment, laboratory tests
Figure 6 – Example of a test setup for ungrounded table-top equipment
Figure 7 – Example of a test setup for ungrounded floor-standing equipment
Figure 8 – Example of test setup for floor-standing equipment, post-installation tests
Figure A.1 – Maximum values of electrostatic voltages to which operators may be charged while in contact with the materials mentioned in Clause A.2
Figure B.1 – Example of a target adapter line attached to current target
Figure B.2 – Example of a front side of a current target
Figure B.3 – Example of measurement of the insertion loss of a current target-attenuator-cable chain
Figure B.4 – Circuit diagram to determine the low-frequency system transfer impedance
Figure B.5 – Typical arrangement for calibration of ESD generator performance
Figure C.1 – Mechanical drawing of a coaxial target (drawing 1 of 5)
Figure C.2 – Mechanical drawing of a coaxial target (drawing 2 of 5)
Figure C.3 – Mechanical drawing of a coaxial target (drawing 3 of 5)
Figure C.4 – Mechanical drawing of a coaxial target (drawing 4 of 5)
Figure C.5 – Mechanical drawing of a coaxial target (drawing 5 of 5)
Figure D.1 – Electric field of a real human, holding metal, charged at 5 kV measured at 0,1 m distance and for an arc length of 0,7 mm
Figure D.2 – Magnetic field of a real human, holding metal, charged at 5 kV, measured at 0,1 m distance and for an arc length of approximately 0,5 mm
Figure D.3 – Semi-circle loop on the ground plane
Figure D.4 – Voltages induced in a semi-loop
Figure D.5 – Example of test setup to measure radiated ESD fields
Figure D.6 – Comparison between measured (solid line) and calculated numerically (dot line) voltage drop on the loop for a distance of 45 cm
Figure D.7 – Comparison between calculated H field from measured data (solid line) and H field calculated by numerical simulation (dotted line) for a distance of 45 cm
Figure D.8 – Structure illuminated by radiated fields and equivalent circuit
Figure D.9 – Radiated H fields
Tables
Table 1 – Test levels
Table 2 – General specifications
Table 3 – Contact discharge current waveform parameters
Table 4 – Cases for application of ESD on connectors
Table A.1 – Guideline for the selection of the test levels
Table B.1 – Contact discharge calibration procedure
Table E.1 – Example of uncertainty budget for ESD rise time calibration
Table E.2 – Example of uncertainty budget for ESD peak current calibration
Table E.3 – Example of uncertainty budget for ESD I30, I60 calibration
Français
SOMMAIRE
AVANT-PROPOS
INTRODUCTION
1 Domaine d'application
2 Références normatives
3 Termes et définitions
4 Généralités
5 Niveaux d'essai
6 Générateur d'essai
6.1 Généralités
6.2 Caractéristiques et performances du générateur de DES
6.3 Vérification du montage de DES
7 Montage d’essai
7.1 Matériel d’essai
7.2 Montage d'essai utilisé pour les essais réalisés en laboratoire
7.3 Montage d'essai pour les essais après installation
8 Procédure d'essai
8.1 Conditions de référence du laboratoire
8.2 Fonctionnement de l'EST
8.3 Exécution de l'essai
9 Evaluation des résultats d’essai
10 Rapport d’essai
Annexe A (informative) Notes explicatives
Annexe B (normative) Etalonnage du système de mesure du courant et mesure du courant de décharge
Annexe C (informative) Exemple d’une cible d’étalonnage satisfaisant aux exigences de l’Annexe B
Annexe D (informative) Champs rayonnés par les décharges personne-métal et les générateurs de DES
Annexe E (informative) Considérations concernant l’incertitude de mesure
Annexe F (informative) Variation des résultats d’essai et stratégie d’intensification
Bibliographie
Figures
Figure 1 – Schéma simplifié du générateur de DES
Figure 2 – Forme d’onde idéale de courant de décharge au contact à 4 kV
Figure 3 – Electrodes de décharge du générateur de DES
Figure 4 – Exemple de montage d'essai pour matériel de table, Essais en laboratoire
Figure 5 – Exemple de montage d'essai pour matériels posés au sol, essais en laboratoire
Figure 6 – Exemple de montage d’essai pour un matériel de table non relié à la terre
Figure 7 – Exemple de montage d’essai pour un matériel posé sur le sol non relié à la terre
Figure 8 – Exemple de montage d'essai pour matériels posés au sol, Essais après installation
Figure A.1 – Valeurs maximales des tensions électrostatiques auxquelles les opérateurs peuvent être chargés lorsqu'ils sont en contact avec les matériaux mentionnés à l'Article A.2
Figure B.1 – Exemple d’une ligne d’adaptation de la cible fixée à la cible de courant
Figure B.2 – Exemple de face avant d’une cible de courant
Figure B.3 – Exemple de mesure de la perte d’insertion d’une chaîne cible de courant-atténuateur-câble
Figure B.4 – Schéma de circuit pour déterminer l’impédance de transfert de système à basse fréquence
Figure B.5 – Arrangement type pour l’étalonnage des performances du générateur de DES
Figure C.1 – Dessin mécanique d’une cible coaxiale (dessin 1 sur 5)
Figure C.2 – Dessin mécanique d’une cible coaxiale (dessin 2 sur 5)
Figure C.3 – Dessin mécanique d’une cible coaxiale (dessin 3 sur 5)
Figure C.4 – Dessin mécanique d’une cible coaxiale (dessin 4 sur 5)
Figure C.5 – Dessin mécanique d’une cible coaxiale (dessin 5 sur 5)
Figure D.1 – Champ électrique d’une personne réelle tenant une pièce métallique, chargée à 5 kV, mesuré à une distance de 0,1 m et pour une longueur d’arc de 0,7 mm
Figure D.2 – Champ magnétique d’une personne réelle tenant une pièce métallique, chargée à 5 kV, mesuré à une distance de 0,1 m et pour une longueur d’arc d’environ 0,5 mm
Figure D.3 – Boucle en demi-cercle sur le plan de sol
Figure D.4 – Tensions induites dans une demi-boucle
Figure D.5 – Exemple de montage d’essai pour mesurer les champs de DES rayonnés
Figure D.6 – Comparaison entre la chute de tension mesurée (trait plein) et la valeur calculée numériquement (trait pointillé) sur la boucle pour une distance de 45 cm
Figure D.7 – Comparaison entre le champ H calculé à partir de la donnée mesurée (trait plein) et le champ H calculé par simulation numérique (trait pointillé) pour une distance de 45 cm
Figure D.8 – Structure illuminée par des champs rayonnés et circuit équivalent
Figure D.9 – Champs H rayonnés
Tableaux
Tableau 1 – Niveaux d'essai
Tableau 2 – Spécifications générales
Tableau 3 – Paramètre de forme d’onde de courant de décharge au contact
Tableau 4 – Cas d’application des DES sur les connecteurs
Tableau A.1 – Conseils pour le choix des niveaux d'essais
Tableau B.1 – Procédure d’étalonnage de décharge au contact
Tableau E.1 – Exemple de budget d’incertitude pour l’étalonnage du temps de montée de DES
Tableau E.2 – Exemple de budget d’incertitude pour l’étalonnage du courant de crête de DES
Tableau E.3 – Exemple de budget d’incertitude pour l’étalonnage de DES à I30, I60